Please read this User’s Manual carefully before using this product.
Plug the adaptor to the Connection Port.
Also plug the adaptor into the mains power supply.
Consult the Therapy Application Table to determine the appropriate Mode level and Time duration for the ailment to be treated

Turn the product on by sliding the Power Button upwards.
The Power Indicator will also turn on.

Press the Mode Button to scroll through the Mode levels. This will cycle through the Mode levels (Low,
Medium and High), as shown by the Mode Indicators.


Press the Time Button to cycle through the Time durations (5, 10 and 15 minutes), as shown by the Time
Indicators. When in use, the chosen Time Indicator will be on constantly and the treatment will count down for the chosen Time duration. If the Time Indicator is flashing, there is not enough pressure being applied.

Hold the device horizontally with the Treatment Head facing upwards. Apply the Ultrasound Gel to the
Treatment Head and spread in a circular motion for a few seconds

Move the Treatment Head in a flat, slow, circular motion over the skin surface of the treatment area. You should aim to apply the Treatment Head evenly (in time) over the surface area.

After the Time duration has been completed, the device will automatically turn off (all Time Indicators will turn off and the therapy will stop). Once your therapy session has been completed, turn off the product by sliding the Power Button downwards. The Power Indicator will turn off.
The product is off when none of the indicators are lit.

There are three considerations when deciding how to treat the injured area:
1 When did the injury occur? If it is in the last seven days, then it is “acute”.
If the injury has existed for a longer period then treat as “chronic”.
2 How deep is the problem area? This refers to the estimated thickness of the tissue where the injury exists in centimetres (or inches).
3 How big is the problem area compared with the size of the Treatment
Head of Revitive Ultrasound?
Use the Therapy Application Tables to create a therapy
Apply the therapy once or twice a day only

The selection of treatment time also depends on the size of the treatment area.
If the treatment area is larger, the treatment time will be longer. For example, if the treatment area is 8cm2 (double the area of the ultrasound head, 4cm2) and the treatment symptom is ACUTE (New Injury), and DEPTH OF INJURY is 2CM [0.8 INCH], according to the table above, the treatment time should be 9 minutes (2 x 4.5 minutes).
Positive effects should be seen in 6 weeks. If symptoms persist, please consult your healthcare professional. The device is suitable for use for a longer period.

The selection of treatment time also depends on the size of the treatment area.
If the treatment area is larger, the treatment time will be longer. For example, if the treatment area is 8cm2 (double the area of the ultrasound head, 4cm2 ) and the treatment symptom is CHRONIC (Old Injury), and DEPTH OF INJURY is 2CM [0.8 INCH], according to the table above, the treatment time should be 3 minutes (2 x 1.5 minutes).
Positive effects should be seen in 6 weeks. If symptoms persist, please consult your healthcare professional. The device is suitable for use for a longer period.
You will not be able to feel the vibration from Revitive Ultrasound because it is operating at an ultrasonic frequency. However, if you are unsure whether the Treatment Head is vibrating, you can do the following test:
Plug the adaptor to the Connection Port.
Also plug the adaptor into the mains power supply.

Turn the product on by sliding the Power Button upwards. The Power Indicator will also turn ON.

Press the Time Button and scroll through to any Time Duration
Important: The device will not work unless a Time Duration is chosen.

Hold the device horizontally with the Treatment Head facing upwards. Place a large drop of water on the
Treatment Head and spread in a circular motion for a few seconds.
Do not immerse in water

Lightly press one finger onto the Treatment Head.
The water will visibly vibrate, demonstrating that the Treatment Head is working correctly.
Important: The Treatment Head only vibrates if the conductive fluid (water or gel) covers the entire surface of the Treatment Head.

For external use only. Do not use on broken skin. Discontinue use if rash or irritation occurs.
Always read the label. Use only as directed. If symptoms persist please consult your doctor.
When using Revitive Ultrasound it is essential to use a liberal amount of Ultrasound Gel in order to reduce friction and assist in the transmission of the ultrasonic waves deep into the tissue. If the gel is inadequate, the effectiveness of the therapy may be reduced by up to 90%.
Choose the area of skin to be treated and use water or alcohol to clean it. Then liberally spread the conductive gel on the skin or directly onto the Treatment Head of the Revitive Ultrasound. During the therapy, the Treatment Head should be kept in constant motion and flat against the surface of the skin.
Do not immerse the device in water.
Do not clean with chemicals.
No part of Revitive Ultrasound is suitable for dishwasher use.
Important: It is recommended to clean the product after every use.
Clean the Treatment Head with a tissue or a soft, damp cloth. This will remove any excess Ultrasound Gel.
Revitive Ultrasound:
When not in use, store the device with the adaptor in a dry room and protect it against extreme moisture, heat and direct sunlight.
Air pressure, humidity and temperature limits for storage:

Revitive Ultrasound Gel:
Wipe nozzle clean and re-cap after each use. Store in a cool, dry place.